Main Products
- Phosphonates Antiscalants, Corrosion
Inhibitors and Chelating Agents - Salts of Phosphonates
-
- Tetra Sodium Salt of 1-Hydroxy Ethylidene-1,1-Diphosphonic Acid (HEDP•Na4)
- Tetra Sodium Salt of 1-Hydroxy Ethylidene-1,1-Diphosphonic Acid (HEDP•Na4)
- 2-Phosphonobutane -1,2,4-Tricarboxylic Acid, Sodium salt (PBTC•Na4)
- Penta sodium salt of Amino Trimethylene Phosphonic Acid (ATMP•Na5)
- Hepta sodium salt of Diethylene Triamine Penta (Methylene Phosphonic Acid) (DTPMP•Na7)
- Potassium Salt of HexaMethylene-DiamineTetra (MethylenePhosphonic Acid) HMDTMPA•K6
- More
- Polycarboxylic Antiscalant and Dispersant
- Biodegradable Antiscalant and Dispersant
- Biocide and Algicide
- Built Scale & Corrosion Inhibitors and Pretreatment Filming Agents
-
- TH-907 Non-P Scale&Corrosion Inhibitor
- TH-503 Scale and Corrosion Inhibitor for Boiler
- TH-503B Scale and Corrosion Inhibitor for Boiler
- TH-504 Scale and Corrosion Inhibitor for Heating Water
- TH-601 Scale and Corrosion Inhibitor for Iron & Steel Plant
- TH-604 Scale and Corrosion Inhibitor for Power Plant
- More
- Corrosion Inhibitor
- Oxygen Scavenger
- Reverse Osmosis Chemicals
- Other
Shandong Taihe Technologies Co., Ltd.
TEL: +86-632-5113066
FAX: +86-632-5112055
E-mail: info@thwater.net
ADD: No.1, Shiliquan East Road, Shizhong District, Zaozhuang City, Shandong Province, P.R.China
TH-410 Bactericide for RO Membrane
Properties:
TH-410 has good penetrating power to microbe cell, it can effectively kill and inhibit bacteria, fungus and alga in RO equipment. TH-410 has the following properties:
1. Non-oxidative bactericide, fast effective.
2. Stripping effective to bacteria mucosity.
3. Compatible with all membranes.
4. Wide pH range, good bio-degradation, no pollution.
5. Operation safe, non-inflammable, non-volatilization.
Specification:
Items | Index |
---|---|
Appearance | transparent liquid |
pH , (1% water solution) | 2.0-5.0 |
Density (20℃)g/cm3 | 1.02 |
Active content % | 3 |
Usage:
Two ways:
1. Input 400ppm to the RO water system through proportional pump, once a time for every two weeks, 30 minutes for each time. This way is suitable for non-stop desalination operation, but the chemical dosage is big;
2. Stop the RO system and clean the system. If the system is seriously polluted, first, clean the system by chemical agents, sterilize next:
(a) Add water to cleaning box, make up TH-410 to concentration 400-800ppm;
(b) Adjust pH <7 (with citric acid or hydrochloric acid, prolong LSB881 half-life)
(c) Circulate for 45 minutes.
Attention:
If water supply contains hydrogen sulfide, soluble ferric ion, manganese ion (chlorine or hydrogen peroxide) TH-410 cannot be used.
Corrosive, avoid to contact with skin and eye.
Package and Storage:
25kg plastic barrel, Storage for one year in room shady and dry place.